IRImplementing rule
ETSO-C44cA1
Fuel Flowmeters
1 Applicability
This ETSO gives the requirements which fuel flowmeters that are manufactured on or after the date of this ETSO must meet in order to be identified with the applicable ETSO marking.
2 Procedures
2.1 General
Applicable procedures are detailed in CS-ETSO, Subpart A.
2.2 Specific
None.
3 Technical conditions
3.1 Basic
3.1.1 Minimum performance standard
Standards set forth in Appendix 1.
3.1.2 Environmental standard
The Fuel Flowmeter must be tested in accordance with SAE AS407C “Fuel Flowmeters” from July 1, 2001, unless otherwise specified by Appendix 1 to this ETSO, SAE AS1055D “Fire Testing of Flexible Hose, Tube Assemblies, Coils, Fittings, and Similar System Components” (sections 4 and 5) from June 1997, and the applicable environmental test procedure as specified by paragraph 2.1 of CS-ETSO, Subpart A, unless otherwise specified by Appendix 1 to this ETSO.
3.1.3 Software
If the equipment design includes a digital computer, see CS-ETSO, Subpart A, paragraph 2.2, for software development.
3.1.4 Airborne Electronic hardware
See CS-ETSO, Subpart A, paragraph 2.3.
3.2 Specific
3.2.1 Failure condition classification
See CS-ETSO, Subpart A, paragraph 2.4.
4 Marking
4.1 General
Marking is detailed in CS-ETSO, Subpart A, paragraph 1.2.
4.2 Specific
None.
5 Availability of referenced document
See CS-ETSO, Subpart A, paragraph 3.
[Amdt ETSO/3]
[Amdt ETSO/7]
[Amdt ETSO/8]
IR · ETSO-C44c — CS-ETSO · ED Decision 2013/012/R · CS-ETSO Easy Access Rules · EAR revision 1 Oct 2026