IRImplementing rule
ETSO-2C205a
Circuit Card Assembly (CCA) Functional Class Delta Equipment Using The Satellite-Based Augmentation Systems (SBASs) for Navigation Applications 1 Applicability
This ETSO provides the requirements which circuit card assembly (CCA) functional Class Delta-4 equipment using the satellite-based augmentation system (SBAS) for navigation applications, that are designed and manufactured on or after the date of this ETSO, must meet in order to be identified with the applicable ETSO marking.
ETSO-2C205a is intended as a means for manufacturers of end-use equipment to rationalise their ETSO-C146e application for a Class Delta-4 sensor by using an ETSO Delta-4 CCA for partial certification credit. ETSO-2C205a is only intended for navigation applications; it is not intended for non-navigation applications.
The standards in this ETSO apply to equipment that is intended to accept a desired flight path and provide deviation commands that are keyed to that path. Pilots and autopilots will use these deviations to guide the aircraft.
An ETSO-2C205a article has a limitation that requires the end-use equipment manufacturer to repeat selected detailed functional tests in the end-use equipment and complete the environmental qualification tests in RTCA document DO-229E (see paragraphs 3.2.2.1 and 3.2.2 below).
2 Procedures
2.1 General
The applicable procedures are detailed in CS-ETSO, Subpart A.
2.2 Specific
None.
3 Technical Conditions
3.1 Basic
3.1.1 Minimum Performance Standard
The applicable standards are those provided for functional Class Delta-4 equipment in RTCA document DO-229E, Minimum Operational Performance Standards for Global Positioning System/Satellite-Based Augmentation System Airborne Equipment, dated 15 December 2016, Section 2, as amended by Appendices 1 and 3 to this ETSO standard. Class Delta-4 equipment is defined in DO-229E, Section 1.4.
3.1.2 Environmental Testing and Test Procedures
3.1.2.1 Environmental Testing
For the applicable environmental standards, see CS-ETSO, Subpart A, paragraph 2.1.
Nevertheless, not all types of environmental test are required for this ETSO standard, as the ETSO article for this ETSO standard is a CCA that will be later integrated into an item of ETSO equipment. Therefore, a minimal set of the environmental test conditions of EUROCAE ED-14/RTCA document DO-160 has been defined (refer to Table 1) in order to verify the performance of the ETSOA article under this minimal set of conditions. The required performance under a particular environmental test is defined in the related test section in RTCA document DO-229E, Minimum Operational Performance Standards for Global Positioning System/Satellite-Based Augmentation System Airborne Equipment, dated 15 December 2016, Section 2.4.
This minimal set is defined in Table 1 below. The chosen test category, associated with the selectable parameters in the test conditions per EUROCAE ED-14/RTCA document DO-160, should be documented in the installation manual as limitations for the installation.
The test sections that are identified as optional are not required for an ETSO-2C205a application. Nevertheless, the ETSO CCA article can be subjected to these test conditions by the applicant on a voluntary basis. When optional sections are not tested, they shall be marked with ‘X’ in the environmental testing summary.
Table 1 — Environmental Qualification Testing minimum set for ETSO-2C205a
| Environmental Test | EUROCAE ED-14/RTCA DO-160 Section | Requirement for ETSO-2C205a |
|---|---|---|
| Temperature | 4.5 | Mandatory If the performance of the module under environmental conditions is dependent on the end-user equipment, it is the responsibility of the applicant to adapt the EUROCAE ED-14/RTCA DO-160 high and low temperature values and temperature variation cycles to the intended installation context. For example, in the case of temperature testing (Section 4.0 of EUROCAE ED-14/RTCA DO-160), the temperature of the environment of the CCA (inside an item of equipment) may be much higher or lower than the equipment level condition expressed in the aforementioned Section 4.0. Therefore, the applicant may qualify their CCA functional sensor based on a chosen intended environment, and, finally, indicate in the installation manual the temperature range for which the correct operation of the CCA is guaranteed. The dissipation constraints required for the CCA and documented in the installation manual should be considered when establishing the temperature test set-up. |
| Altitude | 4.6 | Mandatory |
| Temperature Variation | 5.0 | Mandatory As for Section 4.5, if the performance of the CCA under environmental conditions is dependent on the end-user equipment, it is the responsibility of the applicant to adapt the EUROCAE ED-14/RTCA DO-160 high and low temperature values and temperature variation cycles to the intended CCA installation context. As for Section 4.5, for example, in the case of temperature testing (Section 4.0 of EUROCAE ED-14/RTCA DO-160), in which the temperature of the environment of the CCA (inside an item of equipment) may be much higher or lower than the equipment level condition as expressed in Section 4.0 of EUROCAE ED-14/RTCA DO-160, the applicant can qualify their CCA based on a chosen intended environment, and, finally, indicate in the installation manual the temperature range for which the correct operation of the CCA functional sensor is guaranteed. |
| Humidity | 6.0 | Mandatory |
| Shock (operational) | 7.2 | Optional |
| Shock (Crash Safety) | 7.3 | Optional |
| Vibration | 8.0 | Optional Note: The CCA technology should be assessed for further vibration qualification (EUROCAE ED-14/RTCA DO-160). This preliminary assessment could consider the technology diversity of the components of the CCA, as well as the integration density and number of layers of the circuit card. The assessment could be confirmed by tests conducted on a circuit card that is representative of the CCA technology used in the article under certification. This preliminary assessment of the CCA technology under vibration conditions does not constitute credit for the qualification testing of the CCA when it is integrated into the end-user equipment. |
| Explosion Atmosphere | 9.0 | Optional |
| Waterproof | 10.0 | Optional |
| Fluids Susceptibility | 11.0 | Optional |
| Sand and Dust | 12.0 | Optional |
| Fungus Resistance | 13.0 | Optional |
| Salt Fog | 14.0 | Optional |
| Magnetic Effect | 15.0 | Optional |
| Power Input | 16.0 | Mandatory for CCA interfaces that are directly connected to the aircraft power distribution system. |
| Voltage Spike | 17.0 | Mandatory for CCA interfaces that are directly connected to the aircraft power distribution system. Note: CCA interfaces that are not directly connected to the aircraft power distribution system will be tested after the integration phase as part of the end-user ETSO application or as part of a type-certification programme. |
| Audio Frequency Conducted Susceptibility — Power Input | 18.0 | Mandatory for CCA interfaces that are directly connected to the aircraft power distribution system. Note: CCA interfaces that are not directly connected to the aircraft power distribution system will be tested after the integration phase as part of the end-user ETSO application or as part of a type-certification programme. |
| Induced-Signal Susceptibility | 19.0 | Mandatory for CCA interfaces that are directly connected to the aircraft wiring. Note: CCA interfaces that are not directly connected to the aircraft wiring will be tested after the integration phase as part of the end-user ETSO application or as part of a type-certification programme. |
| Radio Frequency Susceptibility (radiated and conducted) | 20.0 | Mandatory for the conducted susceptibility of CCA interfaces that are directly connected to the aircraft wiring. Note: CCA interfaces that are not directly connected to the aircraft wiring will be tested after the integration phase as part of the end-user ETSO application or as part of a type-certification programme. |
| Emission of Radio Frequency Energy | 21.0 | Mandatory for the conducted emission of CCA interfaces that are directly connected to the aircraft wiring. Note: CCA interfaces that are not directly connected to the aircraft wiring will be tested after the integration phase as part of the end-user ETSO application or as part of a type-certification programme. |
| Lightning-Induced Transient Susceptibility | 22.0 | Mandatory for CCA interfaces that are directly connected to the aircraft wiring. Note: CCA interfaces that are not directly connected to the aircraft wiring will be tested after the integration phase as part of the end-user ETSO application or as part of a type-certification programme. |
| Lightning Direct Effects | 23.0 | Optional |
| Icing | 24.0 | Optional |
| Electrostatic Discharge (ESD) | 25.0 | Optional |
| Fire, Flammability | 26.0 | Mandatory for flammability (ED-14/DO-160 Section 26, Category C). |
3.1.2.2 Environmental Test Procedures for End User
The end user of this ETSO article will be required to verify its performance after integration, and complete the environmental qualification testing after integration of the ETSO-2C205a CCA. In order to allow the end user to properly test the functionality of the CCA functional Class Delta equipment in environmental conditions, the applicant for the ‘functional Class Delta ETSO article’ shall provide the detailed functional test procedures to evaluate the required performance of the functional Class Delta equipment in compliance with RTCA document DO-229E, Minimum Operational Performance Standards for Global Positioning System/Satellite-Based Augmentation System Airborne Equipment, dated 15 December 2016, Section 2.4.
3.1.3 Software
See CS-ETSO, Subpart A, paragraph 2.2.
3.1.4 Airborne Electronic Hardware
See CS-ETSO, Subpart A, paragraph 2.3.
3.2 Specific
3.2.1 Failure Condition Classification
See CS-ETSO, Subpart A, paragraph 2.4.
A failure of the function defined in paragraph 3.1.1 of this ETSO is a:
major failure condition for a loss of function and malfunction of en route, terminal, approach lateral navigation (LNAV), and approach LNAV/vertical navigation (VNAV) position data;
major failure condition for a loss of function of approach localiser performance without vertical guidance (LP), and approach localiser performance with vertical guidance (LPV) position data; and hazardous failure condition for a malfunction of approach (LP and LPV) position data that results in misleading information.
3.2.2 Additional Specific
If the CCA functional Class Delta equipment can satisfy the requirements of RTCA document DO-229E only when used with a particular antenna, the use of that antenna (by part number) shall be a requirement on the installation.
This requirement shall be included in the installation manual as a limitation.
The applicant shall have all the data necessary to evaluate the geostationary (GEO) satellite bias as defined in RTCA document DO-229E, Section 2.1.4.1.5, available for review by EASA.
If the functional Class Delta equipment uses barometric-aiding to enhance the availability of FDE, then the equipment shall meet the requirements in RTCA document DO-229E, Appendix G.
The applicant shall provide to the end user the detailed functional test procedures of the functional Class Delta equipment for the end user to complete the environmental testing.
The intended installation environment and the associated installation constraints should be documented in the installation Manual.
Limitations:
The following specific limitations shall be documented in the IM and in the DDP of the CCA functional Class Delta equipment :
‘The manufacturer of the end-use equipment, using the <insert equipment model> Class Delta CCA, is required to perform the testing described in ETSO-C146<latest revision> Appendix 1 with the Class Delta CCA installed in the end-use equipment.’
‘the manufacturer of end-use equipment is required to complete full environmental qualification at the end-use equipment level.’
4 Marking
4.1 General
See CS-ETSO, Subpart A, paragraph 1.2.
4.2 Specific
The functional Class Delta equipment must be permanently and legibly marked with the operational equipment class (e.g. Class 4) as defined in Section 1.4.2 of RTCA document DO-229E. A marking of Class 4 indicates compliance with the Delta-4 requirements. The functional equipment class (e.g. Delta) defined in Section 1.4.1 of RTCA document DO-229E is not required to be marked.
It is sufficient to declare the proper functional equipment class in the declaration of design and performance (DDP).
5 Availability of Referenced Documents
See CS-ETSO, Subpart A, paragraph 3.
[Amdt ETSO/16]
IR · ETSO-2C205a — CS-ETSO · ED Decision 2020/011/R · CS-ETSO Easy Access Rules · EAR revision 1 Oct 2026