title: "AMC E 750(b) Starting tests — CS-E · Avioverse"
description: "The «declared drainage period» after a false start referred to in CS-E 750(b) is the minimum period necessary to allow surplus fuel to drain from the…"
url: "https://avioverse.aero/regulations/easa/cs-e/subpart-e/amc-e-750-b-starting-tests"
---

# AMC E 750(b) Starting tests

Engines (CS-E) · CS-E · EAR revision 7 Dec 2023

AMC Acceptable means of compliance

## AMC E 750(b) Starting tests

The «declared drainage period» after a false start referred to in CS-E 750(b) is the minimum period necessary to allow surplus fuel to drain from the Engine prior to making a further attempt to start the Engine. The period is measured from the time at which the starter is switched off and/or the Engine fuel cock is closed during a false start.

\[Amdt. No.: E/1]

AMC — CS-E · ED Decision 2007/015/R · CS-E Easy Access Rules · EAR revision 7 Dec 2023

[All rules in SUBPART E – TURBINE ENGINES: TYPE SUBSTANTIATION](https://avioverse.aero/regulations/easa/cs-e/subpart-e)

Consolidated from the EASA Easy Access Rules (revision 7 Dec 2023, extracted 13 Oct 2026) for convenience. Not the official publication — verify against the Official Journal of the European Union and the EASA publications before operational use.