title: "CS 25A1017 Oil lines and fittings — CS-25 · Avioverse"
description: "Each oil line must meet the requirements of CS 25J993 and each oil line and fitting in any designated fire zone must meet the requirements of CS 25J1183."
url: "https://avioverse.aero/regulations/easa/cs-25/subpart-j/cs-25a1017-oil-lines-and-fittings"
---

# CS 25A1017 Oil lines and fittings

Large Aeroplanes (CS-25) · CS-25 · EAR revision 26 Jan 2023

IR Implementing rule

## CS 25A1017 Oil lines and fittings

(a) Each oil line must meet the requirements of CS 25J993 and each oil line and fitting in any designated fire zone must meet the requirements of CS 25J1183.

(b) Breather lines must be arranged so that:

(1) Condensed water vapour that might freeze and obstruct the line cannot accumulate at any point;

(2) The breather discharge does not constitute a fire hazard;

(3) The breather does not discharge into the APU air intake system.

\[Amdt 25/1]

IR — CS-25 · ED Decision 2005/006/R · CS-25 Easy Access Rules · EAR revision 26 Jan 2023

[All rules in SUBPART J – AUXILIARY POWER UNIT INSTALLATIONS](https://avioverse.aero/regulations/easa/cs-25/subpart-j)

Consolidated from the EASA Easy Access Rules (revision 26 Jan 2023, extracted 13 Oct 2026) for convenience. Not the official publication — verify against the Official Journal of the European Union and the EASA publications before operational use.